Place of Origin: | China |
---|---|
Brand Name: | Jufu |
Certification: | ISO9001 |
Model Number: | JFRO-500L |
Minimum Order Quantity: | 1 unit |
Price: | Negotiable |
Packaging Details: | Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping. |
Delivery Time: | 2-4 weeks |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Host Size: | 800x600x1600mm (can Be Customized) | Power: | 1.5KW |
---|---|---|---|
Power Supply: | 220V /380V/460V - 50Hz/60Hz,220V 50Hz Can Be Customized | Operating Pressure: | 0.8-1.2MPa |
Designed Water Inlet: | 1000L/h | Outlet Flow: | 500L/h |
Desalination Rate: | ≥99.5% | Raw Water Pump: | CNP/NYP/GRUNDFOS (Optional) |
Membrane Size: | 4040 | Number Of Membranes: | 2 |
Membrane Elements: | DOW/Hydranautics/Troy/Vontron (optional) | Control Valve: | Manual/Automatic |
Control Valve Brand: | FLECK/RUNXIN | Tank Material: | SS/FRP (Optional) |
Pipe Material: | U-PVC, Stainless Steel (Optional) | ||
High Light: | Industrial Small RO Desalination Plant,250LPH Drinking Water Treatment System,Drinking Water RO Desalination Plant |
250LPH 500LPH 1000LPH 2000 LPH Industrial Small RO Desalination Plant
Product Introduction of RO Water Treatment System
This high pressure water filters ro water treatment plant is used to treat the water from lake, spring, ground water and so on. After treatment, the water can be drinked. The treated water can be used in drinking water filling line, pure water filling line and carbonated drink production line, juice filling line. It is the ideal equipment to filter and disinfect water.
The Basic Working Principle of RO Water Treatment System
After a special high-pressure pump, when the raw water is added to a pressure of 6-20 kg, the raw water permeates through the reverse osmosis membrane with a pore size of only 0.0001 microns under the action of pressure. Chemical ions, bacteria, fungi, and virions cannot pass through, and are discharged with wastewater. Only water molecules and solvents with a volume of less than 0.0001 microns are allowed to pass through.
Technical Specifications of RO Water Treatment System
500LPH Reverse Osmosis System | |
Model | JFRO-500L |
Host Size | 800x600x1600mm (can be customized) |
Power | 1.5KW |
Power Supply | 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized |
Operating Pressure | 0.8-1.2MPa |
Recovery Rate | 50% |
Designed Water Inlet | 1000L/h |
Outlet Flow | 500L/h |
Desalination Rate | ≥99.5% |
RO Frame | SUS304 |
Membrane Size | 4040 |
Membrane Elements | DOW /Hydranautics/Troy/ Vontron (Optional) |
Number of Membranes | 2 |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
Tank Material | SS/FRP (Optional) |
Control Valve | Manual/Automatic |
Control Valve Brand | FLECK/RUNXIN |
Membrane Housing | SS/FRP (Optional) |
Pipe Material | U-PVC, Stainless steel (Optional) |
Application fields of RO water treatment system
Water treatment system treat raw water in several procedures in order to meet the bottled drinking water standard.
This system uses water pressure pump to increase the water supply pressure; sand filter is used to remove Plankton, Moss, Suspension, Colloid and so on. Active carbon filter is used to remove strange smell, chlorine, chloride, organic matter and heavy mental, lower color and optimize water quality. Sodium softer is used to remove the calcium and magnesium ions in water. Micro filter is used to remove the tiny impurity. Hollow fiber Ultra filter can remove impurity, colloid, phenolic compounds, chloride, germ and all the harmful substance, meanwhile keep all beneficial minerals in water. Reverse osmosis can move all the things in the water and to make raw water to be pure water.
Advantages of reverse osmosis:
Continuous operation, stable product water quality
No need for acid-base regeneration
No downtime for regeneration
Saves water for backflushing and cleaning
Produce ultrapure water at high yields (yields can be as high as 95%)
No regenerated sewage, no need for sewage treatment facilities
No need for acid-base storage and acid-base dilution transport facilities
Reduce the building area of the workshop
It is safe and reliable to use, preventing workers from contacting acid and alkali
Reduce operation and maintenance costs
Simple installation and low installation cost
Process flow of RO Water Treatment System
Raw water → Raw water tank → Raw water pump → Multi-media filter (quartz sand filter) → Activated carbon filter → Soft water processor → Precision filter → High pressure pump → Primary reverse osmosis (RO) device → Purified water tank → High pressure pump → Two Stage reverse osmosis → ultraviolet sterilization device → water point.
Photos of reverse osmosis water treatment system
FAQ:
1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)
Model 4040 is designed by 0.25m3/h
Model 8040 is designed by 1-1.2m3/h
2. What is the material of mechanical filter?
Carbon steel, stainless steel, fiberglass
3.What are the multi-way control valves?
Manual control valve, automatic control valve
Multi - way control valve is divided into: filter valve and softening valve
Automatic control valve is divided into: time type and flow type.
Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.